Digesters with increases of temperature

Instruments for wet digestions of liquid or solid samples projected according to G.L.P. Good Laboratory Practise. The range from room temperature to 450¡ãC is able to satisfy all the requirements for standard and Kjeldahl digestions.
The analysed sample is up to 15 ml for liquid or 5 g for solids. The digestion time varies according to the treated material and to the used methods.
The Velp digesters allow a work in reproducible conditions, with a full safety, saving chemicals, work and space in comparison to the traditional methods.
It is possible to remove the evolved fumes using specific accessories without the use of a fume hood.
The structure of the digesters is manufactured from stainless steel and is protected by a special resin and paints giving a high resistance to chemicals and mechanical corrosion.
The heating block holding the test tubes allows an optimal distribution of heat al all the selected temperatures.
Its location within the instrument avoids that in case of liquid spillages these will reach and damage internal parts.
The temperature of the heating block is controlled by dedicated electronics with a microprocessor.
The temperature probe does not require a calibration which is performed by the electronics at each turning up.
This allow a very good precision and repeatability of tests. It is possible to upgrade the software of new version by using a personal computer for the innovative electronics with microprocessor.
It is possible to select up to 20 work programs. For each work program it is possible to select up to four temperatures with the corresponding durations. According to Good Laboratory Practise (GLP) it is possible to send the data related to a performed test to a printer or to a personal computer for their storage.

Important
In digestions evolving fumes, acid gases and corrosive (eg. Kjeldahl) we suggest the use of Velp systems for sucking and neutralizing them:
Recirculating water jet pump type JP code 10.0198,
scrubber type SMS code 10.0199
.

Suitable for
AOAC, EPA, DIN, ISO

Specifications

Instruments Volts Hertz   Code
DK 6 220-240 50-60   F30100182
DK 6 110-120 50-60   F30110182
Different power supply on request
Complementary parts DK 6
Test tubes Ø 42x300 mm A00001080*
Glassware handle with heat shields A00001111
Suction cap A00001096
Support system A00001206
 

A00001080

A00001111

  A00001206  
     
 

A00001096

 
Display: Lighted LCD 2 lines (16x2)
Selection of language 5 selectable languages: I, UK, F, E, D
Selection of measure ¡ãC o ¡ãF
Calibration of temperature automatic by software
Interface serialel RS232
Selectable programs 20 with 4 ramps for each program
Selectable temperatures from room temperature
 450¡ãC/51 ¡Â 842¡ãF
Selectable durations from 001 to 999 min.
Selection of time 1 minute
Continuous operation possible
Diameter and number of holes Ø 42 mm - 6 holes
Power 1100 W
Weight 10 kg
Upon request accessories DK 6
Stainless steel drop collector A00001200
Stainless steel stand for glassware handle A00001097
Printer 220 V A00001009
Printer 115 V A00101009

A00001200

A00001097

  A00001009
Upon request accessories for COD DK 6
COD test tubes Ø 42x200 mm, 200 ml, 29/32 cone A00001040*
Air refrigerants with ground cone A00001041*
PTFE sheats for 29/32 cones A00001042*
Antisplash bells A00001045
Stainless steel glassware handle for COD A00001049
* code number refers to one piece
Performances
Speed of heating from 20 to 420¡ãC 30 minutes
Stability of heating block temperature ¡À0.5¡ãC

Omogeneit¨¤ della temperatura blocco porta provette

¡À0.5¡ãC

Precisione della temperatura del blocco porta provette

¡À0.5¡ãC

A00001042

A00001040

A00001041

A00001045

A00001049

 
Safety
Against over temperature thermostat
Damaged temperature probe thermostat by software shown on the display
152
293 339